Applications
- Slab / Billet / Bloom
- Thin Slab / Tunnel Furnace
- Thin Strip
- Furnace Exit
- Hot Strip / Plate Mill
- Long Products Rolling
- Pipe and Tube
- Wire / Rod
- Heat Treatment Furnace
- Forging
Features
- Designed for harsh environments, up to 300°C (572°F) ambient for the measurement head and up to 70°C for the electronics uni
- Stainless steel lens is utilized with fibre optic cable for operation in extremely high temperatures.
- Includes integrated Air Purging and unique internal baffles to keep front window clean
- Quick access controls for Test button, and sensitivity adjustment
- Easy to install, drop-in replacement for competitive products
- Fast Response time
- Reliable long file, low maintenance operation
- Access to an experienced applications engineering support team (included with all Logika products)
Specifications
- Electronics Unit Operating temp:
- -25˚C to +70˚C (-13˚F to +158˚F)
- Detect Range:
- 0.2-8m
- Response:
- Relay < 20 ms, PNP/NPN < 2ms
- LED Indicators:
- Green = Power on, Red = Target Detect
- Output:
- Relay 30VDC/220VAC @ 5A High on Detect(PNP): max 100mA Low on Detect (NPN): max 100mA
- Power Input:
- 24 VDC, 110VAC, 220VAC @ 5W (select DC or AC at time of order)
- Fibre Optic Cable:
- Standard 2 Meters Long, Other Lengths optionally available
- Power Cable:
- 2 Meters, 11 conductors, Steel Braided
- Senor Detect Infrared Range:
- HT Model: 500 ° 1400°C , 700nm-1200nm LT model: 360°C-1400°C, 900nm-1700nm,
- Self Testing:
- Test Pin
- Protection:
- DC Polarity, Output overload, Short Circuit protection
- Weight:
- 1.3 kg (2.8 LBS)
Downloads